20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.

  • 20 ppm accuracy
  • 13°C – 33°C reference temp. range
  • 100 V @ 25 mA output capacity

799,990.00 635,990.00

In Stock 2-3 Weeks

In Stock 2-3 Weeks

Description

Precision DC calibrator M160 is a portable source of industrial process signals for calibration of multimeters in laboratories as well as on site calibration of evaluation units and other process meters. High load capacity of both voltage and current outputs, robust design and exceptional 20 ppm accuracy over 20°C-wide reference temperature range make this calibrator great for demanding conditions in production facilities. Other functions include thermocouple and RTD simulation, resistance and frequency, all with accuracy and resolution to meet all requirements. With option 91 the calibrator can measure temperature directly at output terminals and compensate the cold junction effect.

Beside M160’s industrial versatility, the calibrator is focused on user friendliness making calibrations simple and straightforward. Main parameters of both generated and measured signals are displayed on large LCD together with function-specific tooltip, providing all relevant details including range, accuracy or load limit. Inspired by recalibration simplicity of M6xx series, the M160 can be easily calibrated using just its front keyboard without any mechanical adjustment inside the instrument.
M160 can be connected to various ATE systems via RS232, USB, LAN or GPIB interface and is fully compatible with WinQbase/Caliber calibration software including the CamOCR module for automated optical UUT readouts.

Available in two models: M160 with U, I, F, TC and M160i with U, I, F, TC, R, RTD

Available Options:

GPIB, USB, LAN extension
Module 19″ rack
160-60 Cable adapter for frequency input
160-70 Cable adapter for R4W/RTD output
91 Pt100 cold junction compensator

Specifications

DC voltage 0 – 100 V, max. burden up to 2.5 W
± 20 ppm / year
DC current 0 – 50 mA, max. burden up to 2.5 W
± 50 ppm / year
Resistance 10 Ω – 300 kΩ, resolution from 100 uΩ
± 200 ppm / year
Temperature TC BCDEG2JKMNRST with cold junction compensation
RTD ± 0.1°C / year
Frequency 0.01 Hz – 15 kHz
± 50 ppm / year

Process Meter

Frequency 0.01 Hz – 100 kHz
± 50 ppm / year

Downloads

Datasheet


M160 Datasheet

Language: English
File Size: 2.61 KB

Manual


M160 Manual

Language: English
File Size: 3.00 MB

Labview Driver


M160 Labview Driver

Language: English
File Size: 3.00 MB

Reviews

There are no reviews yet.

Be the first to review “Meatest M160 Precision DC Calibrator”

Your email address will not be published. Required fields are marked *