Power Supply Voltage Change Simulator

Model:APS xxxxDSR Series

The APS xxxxDSR series is equipped with a four quadrant bipolar amplifier, which simulates various voltage changes on the wiring harness and can generate voltage drops, short-term interruptions, and other voltage changes.

In Stock
Enquire Now

Description

The APS xxxxDSR series is equipped with a four quadrant bipolar amplifier, which simulates various voltage changes on the wiring harness and can generate voltage drops, short-term interruptions, and other voltage changes. The output internal resistance can be adjusted. Built in signal source, users can edit and output any wave through PC software. It can also be used as a battery powered analog and DC voltage source. During laboratory testing, APS xxxxDSR replaced the vehicle battery, generating Pulse 2b, Pulse 4, sine wave noise, and other complex voltage variation waveforms. Very suitable for ISO 7637/16750 conduction transient testing. At the same time, the APS xxxxDSR series complies with numerous international/national standards and automotive manufacturer standards. As a powerful DC power supply, it supports 12V, 24V, 42V, 24V, and 48V system automotive testing.

Features

  • Four quadrant bipolar power supply;
  • Adjustable output impedance;
  • The maximum test voltage can reach 80 V;
  • The maximum test current can reach 100 A;
  • Automatic compensation function for voltage drop;
  • High bandwidth output frequency up to 300 kHz;
  • Built in signal source can edit any wave;
  • Support AC voltage and current closed-loop testing;
  • Can simulate various power supply waveforms, such as superimposed noise, etc;
  • Ethernet and RJ45 interfaces, used for PC remote control and printing test reports;
  • Output voltage and current monitoring/protection function.

<

System overall connection diagram

 

ISO 16750-2 2023 Sweep Frequency Closed Loop Layout

The naming convention for instruments is as follows, using APS 80I100DSR as an example:
APS: Power supply voltage change simulator;
80: Maximum voltage 80V; 40:40V, 60:60V;
I: The level representing negative voltage, D:0V、E:-15V、F:-20V、G:-40V、H:-60V、I:-80V;
100: Output current level, can be divided into 10A, 30A, 50A, 100A;
D: Four-quadrant, bipolar power supply (if D is not included in the model, it is a unipolar power supply);
S: Built in AWG signal generator (without S in the model, there is no built-in signal generator);
R: The output impedance is adjustable (if there is no R in the model, the output impedance is not adjustable).

Standard

  • GMW3172 June 2015
  • Ford EMC-CS -2009revl
  • Mazda MES PW 67600
  • BMW GS 95003-2
  • FIAT 7-Z0441
  • FIAT 7-Z0441 April 2008
  • Ford ES-XW7T-1A278-AC OCT 2003
  • Volvo Volvo STD 515-0003 2008
  • JEELY J7110982A 2016
  • SMTC 3800001 2014
  • BMW 600 13.0 (T1)
  • BMW 600 13.0 (T2)
  • BMW GS 95002 (2010)
  • BMW GS 95024-2-1 2010
  • GMW3172 July 2010
  • VW TL82066 2006-11
  • VW 80000 2013-06
  • Peugeot B21 7110 July 2005
  • MBN 10284-4 2011
  • MBN 10 284-2 2008
  • QFPT2800001 2011
  • ISO 7637-2
  • ISO 16750-2
  • GB 28046.2

Specifications

Technical Parameters
APS 40G30DSR
Output Voltage -40 V – +40 V
Output Current Max 30 A,continuity
Peak Current 60 A, duration greater than 200 ms
Frequency Range DC-300 kHz full frequency signal,

resolution: 0.01Hz, accuracy: ± 5%

Vpp Max 32 V(DC – 300 kHz) accuracy < 3V ± 0.1 V
≥ 3V ± 0.2 V
Ipp Max 60 A
APS 80I100DSR
Output Voltage -80 V – +80 V
Output Current Max 100 A,continuity
Peak Current 200 A, duration greater than 200 ms
Frequency Range DC-300 kHz full frequency signal,
resolution: 0.01Hz, accuracy: ± 5%
Vpp Max 32 V(DC – 300 kHz) accuracy < 3V ± 0.1 V
≥ 3V ± 0.2 V
Ipp Max 200 A
Internal Signal Source
Frequency Range DC – 500 kHz
Waveform Type DC waveform, oblique wave, triangular wave, sine wave, square wave, sweep wave, exponential wave, oscilloscope stored data waveform, user-defined waveform editing, irregular and irregular arbitrary wave
Can Set Waveform Parameters Amplitude, duration, frequency, DC offset, rectification, cycle duty cycle, phase angle, trigger
Amplitude and Bias Changes Static, linear, logarithmic
Frequency Variation Static, linear, logarithmic
Linear stepping range: 10Hz to 10kHz
Start and End Phase Control 0-359 °, 1 ° step setting
Rectification None, positive, negative, bridge rectifier
Introduce File Types CSV
Introduce The Number of Waveform Points In The File 8k
Segments That Make Up The Waveform Each waveform can have up to 1000 segments, and each segment can be composed of several types of waveforms
Duration of The Segment DC waveform: 10 μs -299 h
Triangular wave, sine wave, square wave, sweep wave:
1 ms-299 h
Exponential wave, oscilloscope stored data waveform: 0.001 – 20 s
Number of Times 1-9999 times
General Parameters
Analog Signal
Input
BNC, 0 to ± 10 V (maximum 0 to ± 10 V
depending on actual instrument configuration)
Sense Signal
Input
BNC
Source
Impedance
10 mΩ~200 mΩ (10 mΩ step)/No internal resistance
Voltage
Compensation
Accuracy
± 0.1 V
Maximum
Voltage
Compensation
Value
4 V
Voltage Offset > 90%, recovery time < 10 μs
Voltage
Fluctuation
Ur<0.2 Vpp
Boosting Time <3 μs/10 μs (12 V DC to 13 V DC; 0 V to Vmax DC)
Serial Interface LAN Ethernet and RJ45
External Signal
Amplification
Ratio
1:10
Ambient
Temperature
15 ~ 35 ℃
APS 40xxDSR APS 80xxDSR
Supply Voltage AC 220 V,±10%,
45-65 Hz
AC 380 V,±10%,
45-65 Hz
Size 19 inches/8U 35U
Weight About 37 kg About 150 kg

Downloads