I type 10/350 impulse current test system

Model:LCG A series

Impulse current test system LCG A series is mainly used to simulate high current generated by lightening to check the impact on power supply system and electric appliance.

In Stock
Enquire Now

Description

Impulse current test system LCG A series is mainly used to simulate high current generated by lightening to check the impact on power supply system and electric appliance. It can conduct impulse current tests with high integration, intelligent control and easy operation. There are multiple grades for output by different main circuit unit. With setting parameters on setting page, it can conduct the test automatically with one button.

  • Human computer interface of colorful touch screen, easy to operate;
  • PLC control system, stable and reliable operation;
  • Different control modes: manual, automatic or programmable, as per different needs;
  • Multiple grades of output ranges, test current down to 1kA;
  • Charging mode of continuous current, effectively save energy;
  • Abnormal protection by audible and visual alarm;
  • Automatic measure and analyze parameters of different waveforms.

Standard

  • TB/T 3074
  • IEC 61643-1
  • GB/T 11032
  • GB 18802.1
  • UL1449
  • YD-T 5098
  • YD/T 1235.2

Specifications

Technical Parameters
Item 10/350μs current wave
Output peak 10kA,15kA,25kA,35kA,50kA,100kA
T1 front time 10μs(<50μS)
T2 wave tail time 350μs±10%
Reversed overshoot none
Front oscillatory <5%
Voltage polarity +/-, (automatic switch)
Waveform switch Automatic switch
Charging time 10s~999s
Charging voltage
instability
Less than 1%
External sync input 50Hz
Trigger mode Automatic or manual, single trigger available
Trigger malfunction rate Less than 1%
Trigger range 100% rated charging voltage
Phase test range 0~360°
Operating load test internal,0~500V,5A continuous supply
Display screen 10 inch TFT color touch screen
Measurement display
resolution
Better than 3%
DUT MOV, TVS, GDT, SPD, mains surge protection device
DUT residual voltage <5kV
Current measurement
(optional)
Internal test box, Rogowski coil measurement, panel BNC output
Voltage measurement
(optional)
Internal test box, pure-resistance voltage divider, panel BNC output
Oscilloscope MDO3012, optional
Insulation strength ≤500V RMS(common port COMMON to ground reference PE)
General data
Power supply AC220V±10%,50/60Hz,10A
Temperature -10-+40℃
Humidity 35%-85%RH(no condensation)
Ground resistance No more than 0.5Ω
Structure Open style, control and base separated
Size of test room Depends on model(base)+3M*5M(control)
Control table 1.8M(width)*1.1M(height)*1M(depth)
No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Wave

form of mains voltage is sine wave. The THD is <5%.

Technical parameters of standard model
Model LCG 10A LCG 15A LCG 25A LCG 35A LCG 50A LCG 100A
Current
peak
0.5~10kA 1~15kA 1~25kA 1~35kA 1~50kA 1~100kA
Stored energy 36kJ 56kJ 100kJ 150kJ 200kJ 400kJ
Charging voltage 10kV 14kV 14kV 14kV 14kV 14kV
Supply mains AC220V 32A AC220V 50A AC220V 50A AC220V 100A AC220V 100A AC220V 200A
Installation frame frame frame frame frame Split frame

Attached table one:

Other test waveform and output capacity
No. Waveform Type Max. Output peak Charging voltage Equivalent output impedance
D 10/1000 Current wave 30kA 15kA 0.5Ω
E 100/1000 Current wave 30kA 15kA 0.5Ω
P Other waveform can be customized

*Internal one waveform for each equipment. Other waveform can be customized.