CCS600 is an intelligent multifunctional compact immunity (EMS) test system, as per all the requirements of international standards and product standards for transient pulse, surge and voltage dip.

In Stock
Enquire Now

Description

CCS 600 is an intelligent multifunctional compact immunity (EMS) test system, which meets all the requirements of international standards and product standards for transient pulse, surge and voltage dip. Its test voltage is up to 6 kV. CCS series are the best choice for full compliance immunity test solutions. With built-in fully automatically single-phase CDN, it not only meets the immunity testing requirements of CE and CCC certification for single-phase EUTs, but also be capable of performing three-phase-five-line EUTs tests by using automatically controlled external CDNs (up to 100 A) of our company. Various enclosures needed are available to satisfying types of needs such as power frequency magnetic field tests.

Features:

  • 5.7” color touch screen
  • Surge failure detection
  • Data acquisition of surge voltage and current
  • Test sequence function
  • Built-in multifunctional testing modules
  • Built-in single-phase fully automatically CDN,AC 250 V 16 A;DC-1 (resistive load) 250 V 16 A
  • Optional for external three-phase CDN modules
  • Ethernet and RJ45 ports, used for PC remote control, test report documentation and print etc.

Standard

  • IEC 61000-4-5
  • IEC 61000-4-9
  • IEC 61000-4-4
  • IEC 61000-4-8
  • IEC 61000-4-11
  • IEC 61000-4-29
  • IEC 61008-1
  • IEC 61009-1
  • GB/T 17626.5
  • GB/T 17626.4
  • GB/T 17626.8
  • GB/T 17626.9
  • GB/T 17626.11
  • GB/T 17626.29
  • EN 61000-4-5
  • EN 61000-4-9
  • EN 61000-4-4
  • EN 61000-4-11
  • EN 61008-1
  • EN 61009-1
  • EN 61543
  • EN 61000-4-8
  • EN 61000-4-29
  • ANSI/IEEE C62.41

Specifications

Technical Parameters
Display Screen 5.7” TFT color touch screen Power Supply AC 110 V/220 V(士10%), 50 Hz /60 Hz, (±5%) (default AC 220 V 50 Hz in mainland China)
Fuse 6 A Max. Power Consumption 200 W
Memory Space Infinite(PC) Communication Mode Ethernet, RJ45
Dimension 19”/6U Weight Approx. 41 kg
Ambient Temperature 15℃-35℃ Relative Humidity 45%-75%
Atmospheric Pressure 86 kPa-106 kPa
EFT/burst Tests as per IEC 61000-4-4
Test Voltage 0.25 kV-4.8 kV(±10%) Source Impedance 50 Ω
Polarity Positive, negative, alternative Rise Time 5 ns(±30%), 50 Ω load, 1000 Ω load
Pulse Waveform 5/50 ns, 50 Ω and 1000 Ω load Pulse Frequency 0.1 kHz-1000 kHz
Pulse Duration 50 ns±30%, 50 Ω load Burst Duration 0.075 ms-750 ms
50 ns-15/+100 ns,1000 Ω load Test Duration 1 s-9999 s
Burst Cycle 11 ms-9999 ms Synchronization 0° – 360°, 1° step or random
Trigger Mode Automatic, manual or external trigger CDN Internal single phase automatic CDN: Single-phase-3-line AC 220 V 16 A Max 250 V
Surge Tests as per IEC61000-4-5
Test Voltage 0.3 kV-6 kV(±10%) Test Current 0.15 kA-3 kA(±10%)
Voltage Waveform Front time: 1.2 μs (±30%), Time to half value: 50 μs (±20%) Source Output Impedance 2 Ω
Current Waveform Front time: 8 μs (±20%), Time to half value:20 μs (±20%) Coupling Capacitance 9 μF, 18 μF
Polarity Positive, negative, alternative Pulse Cycle 5 s-180 s (the shortest depends on test voltage)
Coupling Resistance 10 Ω, 0 Ω coupling resistor Either IEC standard mode or customized mode is optional Number of Test 1–999
Surge Voltage and Current Peak Detection Front panel BNC output, surge voltage: 1000 V:1 V Surge current :500 A:1 V 3 digits on display Synchronization 0° – 360°, 1° step or random
Trigger Mode Automatic, manual or external trigger CDN Built-in single phase automatic CDN

Single-phase-3-line AC 220 V 16 A Max. 250 V

PFMF Tests as per IEC61000-4-8 with optional module MFT 400/1200 or VMT series
Magnetic Field Strength TCXS 111 Single-turn coil: 1 A/m -100 A/m (continuous)

100 A/m -400 A/m (1 s-10s in short time)

TCXS 113 Single-turn coil: 1 A/m -300 A/m (continuous)

300 A/m -1200 A/m (1 s-10 s in short time)

Current Distortion Rate <5%
Current Waveform 50 Hz/60 Hz sine wave Operating Current Range for Short Time 120 A-500 A
Continuous Operating Current Range 1 A-120 A Test Duration 1 s-28800 s
Magnetic Field Output Accuracy Deviation 1dB(minimal magnetic field intensity like 1A/m needs to be adjusted manually before tests.) Waveform Interval 1 s-9999 s
Coil Size 1000 mm *1000 mm or others Trigger mode Auto, Manual, External signal trigger
Coil Turn Single-turn /three-turn Coil shape Rectangle or others
Output Magnetic Field Strength Test Sequencing setup
Pulse Magnetic Field Tests as per IEC 61000-4-9 with optional module PMC 1200
Output Magnetic Field Range 100 A/m-1200 A/m Waveform Rise time:6.4 μs (±30%); duration: 16 μs (±30%)
Output Current 100 A-2000 A Polarity Positive, negative, alternative
Synchronization 0°- 360°, 1°step or random Pulse Cycle 5 s-99 s(the shortest depends on test current)
Trigger Mode Automatic, manual or external trigger Coil Shape Rectangle
Number of Test 1-999 Model of Coil TCXS 111
Coil Size 1000*1000mm Output Magnetic Field Strength Test sequencing setup
Coil Turn single
Power Fail Tests as per IEC 61000-4–11 (with Optional Module VVT or VMT series) & IEC 61000-4-29
EUT Max. Voltage 250 V AC, 220 V DC EUT Max. Current AC/DC 16 A continuous current; AC 20 A continuous 5 s;

40 A continuous 3 s;

500 A impulse current

EUT Current and Voltage Measurement LCD display, BNC terminal: voltage 100:1, current 10 A:1 V Dip Level 0%-100%(for VVT/VMT series)

0%,40%,70%,80%(for VVTxxxxSFseries)

Interruption level 0% Dip and Interruption Interval 5 ms-9999 ms
Dip and Interruption Duration 0.1-9999 cycle or 1 ms-9999 ms Dip and Interruption Rise/Fall Time 1 µs -5 µs (100 Ω load)
Dip and Interruption Test Duration 1 s-9999 s Time of Voltage Variation Decreasing 500 ms-9999 ms (50%-100%) or abrupt (same with rise/ fall time for dips and

interruption)

1000 ms-9999 ms (0%-100%) or abrupt (same with rise/ fall time for dips and

interruption)

Voltage Variation Level 0-100% Duration after Voltage Variation Decreasing 10 ms-99999 ms
Time of Voltage Variation Increasing 500 ms-9999 ms(50%-100%)

1000 ms-9999 ms(0%-100%)

Trigger Mode Automatic, manual or external trigger
Synchronization 0°- 360°, 1° step or random
Models Selection
Name Model IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-8 IEC 61000-4-9 IEC 61000-4-11 IEC 61000-4-29 CDN single- phase-3-line
Compact Immunity Test System CCS 600
EFT/Burst CDN EFTN 3816T
Surge CDN SPN 3816T
EFT/Burst and Surge CDN SEPN 3816T
SEPN 3832T
Power Frequency Magnetic Module MFT 400
MFT 1200
AC Voltage Dips, Short Interruption and Variation Module VVT 2216S
VVT 2216SV
Power Fail and Power Frequency Magnetic Module VMT 2216S
VMT 2216SV
Pulsed Magnetic Field Converter PMC 1200

Downloads

Adobe PDF

Reviews

There are no reviews yet.

Be the first to review “Compact immunity simulator CCS 600”

Your email address will not be published. Required fields are marked *