Combination Wave Simulator CWS

Model:CWS X00G/SPN 38XXT

The Combination Wave Surge Simulator CWS x00G/SPN xxT series is a particularly designed system for the surge immunity tests for three phase EUTs with automatic switching of external CDN.

In Stock
Enquire Now

Description

Almost all electrical equipment and devices can be affected by the unidirectional surges caused by over-voltages from switching and lightning transients. CWS x00G/SPN xxT series is a particularly designed system for the surge immunity tests for three phase EUTs with automatic switching of external CDN, and can also be used for pulsed magnetic field immunity tests. The products are in full compliance with CE and CCC requirements. The series includes 6 kV & 8 kV generators CWS 600G & CWS 800G, and SPN with EUT load capacity: AC 380V or 450 V, & 16 A – 100 A or customizable.

Features

  • 5.7” color touch screen front panel operation.
  • Surge voltage up to 6 kV/8 kV, surge current up to   3 kA/4 kA.
  • Surge voltage/current monitoring on LCD display (optional).
  • Fault detection (optional).
  • Test sequencing, easy operation.
  • External automatic 3-phase 5-wire CDN.
  • Can be used for IEC 61000-4-9 tests with optional induction coils.
  • RJ45 for PC control & test report printing.

Standard

  • IEC 61000-4-5
  • IEC 61000-4-9
  • IEC 61850-3
  • IEC 61326
  • GB/T 17626.5
  • UL1449
  • ITU-T K.20
  • ITU T K.45
  • ITU-T K.12

Specifications

General Parameters
Display 5.7” TFT color touch screen
Operating power supply AC 110 V/220 V ±10%, 50/60 Hz
Fuse 6 A
Max power 250 W
Storage space Unlimited (PC)
Communication method Ethernet, RJ 45
External control method D-sub 25p
External triggering input BNC, 5 V TTL
CRO triggering input BNC, 5 V TTL
Operation control input BNC, 5 V TTL
External sync input 45 Hz – 65 Hz,

20 V – 500 V between different terminals;

0 – 500 V between terminals & the case;

Alarm indicators output 0-220 V AC, 10 A;

0-48 V DC 3A (subject to the type of external signal indicators)

Safety circuit No operation when the safety circuit is open
Fault detection Shown on LCD display, operation will be stopped
Operating status LED indicators on front panel, LCD display
Grounding method Grounding strips
Grounding connection Standard 1 m coaxial cable
Dimension 19“, 6U x 2 units
Weight Approx. 30 kg
Temperature 15 ~ 35 ℃
Humidity 45% ~ 75%
Air pressure range 86kPa ~ 106kPa
Technical Parameters (IEC 61000-4-5)
Test voltage 0.3 kV–6.0 kV/8.0 kV, ±10%

(CWS 600G/800G)

Voltage waveform Tf: 1.2 μs ±30%,

Td: 50 μs ±20%

Test current 0.15 kA – 3.0 kA/4.0 kA, ±10%
Current waveform Tf: 8 μs ±20%,

Td: 20 μs ±20%

Source impedance 2 Ω
Output polarity +, -, +/-
Coupling capacitance 9 μF, 18 μF
Coupling resistance 10 Ω, 0 Ω

(as per IEC standards or customized)

Surge period 5 s – 99 s (the min. depends on test voltage)
Test times 1 – 999
Triggering mode Automatic, manual or external
Synchronization 0° ~ 360°, 1° step or random
External CDN
Model No. SPN 38XXT
Coupling Capacitance 9 μF / 18 μF
Decoupling Inductance 1.5 mH
Coupling Mode Automatic, test sequence
EUT load capacity Max:AC 380 V 16 A/32 A

3-phase-5-wire

Downloads

Adobe PDF

Reviews

There are no reviews yet.

Be the first to review “Combination Wave Simulator CWS”

Your email address will not be published. Required fields are marked *