High voltage high-power intelligent

Model:CWS 600G/SPN 15100T

CWS 600G/SPN 15100T is a specially designed system which can fully meet CE and CCC.

In Stock
Enquire Now

Description

CWS 600G/SPN 15100T is a specially designed system which can fully meet CE and CCC. The system has been built-in SPN 15100T three -phase five-wire high power fully automatic CDN to meet the requirements of new energy test system and high power load test with advantages of high reliability, stable performance and easy to use, etc. EUT high voltage high power load capacity is DC 1500V 100A, AC 700V 100A three phase five wire. Other EUT voltage and current levels can be customized according to customer’s requirements.

  • EUT DC load capacity: DC 1500V 100A
  • EUT AC load capacity: AC 700V 100A three-phase five wire
  • Semi-conductor switch technology,EUT power automatic switching over
  • EUT voltage and current detection
  • Overvoltage, over current and overheating protection
  • Setting test voltage, polarity and phase sync angle by scheduling and fully automatic network switching over
  • Phase angle superposition for any line

Standard

  • IEC 61000-4-5
  • IEC 61000-6-2
  • IEC 61000-6-1
  • GB/T 17626.5
  • EN 61000-4-5

Specifications

Technical parameters
Combination wave simulator CWS 600G
Test voltage range 0.3kV-6kV,(±10%)
Test current range 0.15kA-3kA(±10%)
Voltage waveform Front time:1.2μs±30% time to half value:50μs±20%
Current waveform Front time:8μs±20% time to half value:20μs±20%
Source output impedance 2 ohm
Output polarity +/-/alternate
Surge voltage Surge voltage:1000V:1V surge current:500A:1V
Current peak detection LCD display the measured value with 3 digits

IEC standard mode or self-defined mode

Coupling resistance 10 ohm, 0 ohm coupling resistance, IEC standard mode or self-defined mode
Pulse cycle 5s-99s(The shortest depends on test voltage)
Test times 1-999
Trigger mode Automatic, manual and external
Synchronization 0-360°,resolution 1° step or random
Network Module SPN 15100T
Three-phase fully automatic Coupling/ decoupling Network Surge combination wave test, voltage up to 8.0kV(1.2/50us),current up to 4.0kA(8/20us)
EUT load capacity Peak value 400A
EUT switching over mode Auto switching over
Phase synchronization L1、L2、L3、N、PE,arbitrary L-L, L-N phase angle superposition
Coupling paths L1、L2、L3、N、PE, arbitrary combination path
Coupling switching over mode Auto switching over
Coupling capacitance 9uF、18uF
Coupling resistance 10 ohm、0 ohm

Optional for IEC standard mode or self-defined mode

Coupling attenuation <2 dB
Residual pulse voltage at the injection of EUT Less than 15% of applied test pulse voltage or 2 times rated voltage peak of coupling/decoupling network
Cabinet size 19”/35U
Weight Approx.200Kg

Downloads

Adobe PDF

Reviews

There are no reviews yet.

Be the first to review “High voltage high-power intelligent”

Your email address will not be published. Required fields are marked *