Communication surge immunity tester

Model:CWS 2000C & CWS 2000T

CWS 2000C&CWS 2000T communication surge immunity tester is a high testing equipment specially designed to simulate surge pulse interference.

In Stock
Enquire Now

Description

CWS 2000C & CWS 2000T communication surge immunity tester is a high testing equipment specially designed to simulate surge pulse interference. CWS 2000T can generate high voltage pulse waveforms of 10/700μs and 5/320μs, meeting the requirements of IEC 61000-4-5 and other standards.
The performance of CWS 2000C &CWS 2000T fully meets the requirements of EU CE certification and CCC certification for the immunity test of the tested equipment.

Features:

  • 5.7-inch colorful touch screen.
  • Voltage can reach 20 kV.
  • As per IEC 61000-4-5 and GB/T 17626.5.
  • Display peak voltage / current on LCD.
  • Test sequencing and scheduling, easy test setting.

Standard

  • IEC 61000-4-5
  • IEC 61643-1
  • GB/T 17626.5
  • GB/T 16927.1
  • TB/T 3498-2018

Specifications

Instrument introduction
CWS 2000C Communication surge immunity tester control
CWS 2000T 10/700μs&5/320μs communication surge generator
Technical Parameters
Test Voltage Range 0.5 kV ~ 20 kV ±10%
Voltage Waveform Front time: 10μs ±30%;

Pulse width: 700μs ±20%

Test Current Range 12.5 A ~ 500 A ±10%(40 ohm)
Current Waveform Front time: 5μs ±20%;

Pulse width: 320μs ±20%

Source Impedance 15 ohm, and 40 ohm to select
Output Polarity +, -, +/-
Pulse Period 11 s ~ 180 s (the min. depends on the test voltage)
No. Of Tests 1 ~ 999
Peak voltage monitor BNC output : 2000 V:1 V; LCD display
Peak current monitor BNC output : 100 A:1 V; LCD display
Triggering Method Automatic / manual / external triggering
Test mode Test parameter scheduling setting
General Parameters
Display 5.7-inch colorful touch screen
Operating Power Supply AC 110 V / 220 V±10%, 50 Hz / 60 Hz (AC 220 V in China)
Fuse 6 A
Max Power 1000 W
User storage space Infinite(PC)
Communication Method Ethernet and RJ 45
Operating State Indicators Front panel LED, LCD
Malfunction Detection Malfunctions will be shown on LCD while the operation will be stopped.
Monitor output way 1 meter coaxial-line
Dimension 35 U
Weight Approx. 108 kg
Source Impedance Approx. 108 kg
Operating Temp. 15℃ ~ 35℃
Operating Humidity 45% ~ 75%
Operating Air Pressure 86kPa ~ 106kPa