Automatic Multifunctional Lightning

Model:CWS 2000TS

Automatic Multifunctional Lightning Surge Immunity Test Station? CWS 2000TS is designed in accordance IEC 61000-4-5, GB/T 17626.5 etc for performing surge immunity tests.

In Stock
Enquire Now

Description

Automatic Multifunctional Lightning Surge Immunity Test Station – CWS 2000TS is designed in accordance IEC 61000-4-5, GB/T 17626.5 etc for performing surge immunity tests. Its max pulse voltage is 20 kV, and its max pulse current is 20 kA.
Designed with the 3rd generation smart control platform, CWS 2000TS achieves great human-machine interactions with unique color touch screen, simple operation with easy test scheduling, parameters setting and automatic execution. It boasts of high-level system integration, intelligent control, easy operation and timesaving.

Features

  • 5.7” color touch screen front panel
  • In compliance with IEC 61000-4-5, GB/T 17626.5 etc
  • Warning system: automatic detection of plenty errors
  • Remote control with LAN interface port
  • Enhanced safety with built-in
  • 19” standard cabinet

Standard

  • IEC 61000-4-5
  • IEC 61643-1
  • GB/T 17626.5
  • ITU-T K.21
  • ITU T K.44
  • ITU T K.45

Specifications

Technical Parameters
Waveform 1.2/50 μs, 8/20 μs
Open-circuit voltage 2~20 kV±10%
Output voltage waveform 1.2±30%、50 μs±20%
Output impedance 2 Ω
Output short-circuit current 1~10 kA±10%
Output current waveform 8/20 μs±20%
Pulse Current Module (8/20 μs)
Charging voltage 2-10 kV
Output voltage waveform 8/20 μs±20%
Output impedance 0.5 Ω
Output short-circuit current 4~20 kA ±10%
Pulse Current Module (10/350 μs)
Charging voltage 2-10 kV
Output current waveform 10(-10%+100%), 350 μs±20%
Output impedance 13 Ω
Output short-circuit current 0.15-0.75 kA
Pulse Current Module (10/1000 μs)
Charging voltage 2-10 kV
Output current waveform 10(-10%+100%)/1000 μs±20%
Output impedance 40 Ω
Output short-circuit current 0.1-0.25 kA
Pulse Voltage Module (1.2/50 μs)
Charging voltage 2-20 kV ±10%
Output voltage waveform 1.2/50 μs
Output impedance 500 Ω (to be customized)
General parameters
Triggering mode Synchronous/asynchronous;

Automatic/manual;

Capable of single triggering

Working Power Source AC 110 V/220 V (±10%),50/60 Hz
Working Temperature 15 ℃ – 35 ℃
Working Humidity 45%-75%
Working air Pressure 86 kPa-106 kPa
Dimension 19”/35U(600x800x1820)