Combination Wave Surge Simulator CWS

Model:CWS 600T

The combination wave lightning surge simulator CWS 600T is designed to conduct surge test onto communication port.

In Stock
Enquire Now

Description

The combination wave lightning surge simulator CWS 600T is designed to conduct surge test onto communication port, which is capable of generating 10/700 μs, 5/320 μs combination wave with maximum test voltage up to 6.0 kV.

Features:

  • 5.7 inches color touch screen on front panel.
  • Maximum test voltage up to 6.0 kV.
  • Telecom wave 10/700 μs.
  • Error alarm notification.
  • LAN Ethernet Interface for PC remote control.

Standard

  • IEC 61000-4-5
  • IEC 61326
  • IEC 60255-22-5
  • IEC 61850-3
  • EN 60255-22-5

Specifications

General parameters
Display 5.7” TFT color touch screen
Working Power AC 110 V/220 V(±10%),50 Hz /60 Hz(Default in mainland China:220 V)
Fuse 6 A
Max. Power 200 W
Storage Space Unlimited (PC)
Communication Method Ethernet, RJ45
Failure Detection The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument.
Working Status Indication LED indication and LCD display on front panel
EUT Power Injection Line φ4 mm banana plug
Detection Output Mode Standard 1m coaxial cable
HV Output Mode 4 mm2 banana plug(HV line)
Operating Temperature 15 ℃ – 35 ℃
Operating Humidity 45%-75%
Operating air Pressure 86 kPa-106 kPa
Dimension 19”/ 6U
Weight About 30 Kg
Technical Parameters
Combination Wave
Test Voltage 0.3 kV –6 kV ± 10%
Telecom Wave
Test Current 7.5 A-150/200 A (±10%)
Voltage Waveform Rise time :10 μs±30%,

time to half value:700 μs±20%

Current Waveform Rise time : 5 μs±20%,time to half value: 320 μs±20%
Source Impedance 15 ohm /40 ohm (Switched automatically)
Polarity Positive, negative, alternative
Pulse Repetition 6 s – 180 s (The shortest time depends on test voltage)
Counter 1 – 999
Triggering Mode Automatic, manual, or external triggering
CDN External CDN model No. (options):

CDN-405AF8

CDN-405T8

CDN-405T8A1

Output voltage up to 8 kV and 10 kV are available for customization.