Description
The SEPN 69200T three-phase automatic coupling/decoupling network for EFT/Burst and surge immunity tests is designed according to test requirements of IEC/EN 61000-4-4 and IEC/EN 61000-4-5, features stable performance and convenient operation. The device is used together with CCS series, CWS series and EFT series of 3ctest. It can couple surge and EFT/Burst wave pulses onto three-phase mains supply system with voltage AC700 V(three-phase-5-line)/DC 1500 V and current 200 A and can also be customized according to actual EUT load.
Features:
- EUT DC load capacity DC 1500 V 200 A.
- EUT AC load capacity AC 700 V 200 A three-phase-five-wire.
- EUT power supply automatic switching.
- Over-current protection.
- Test sequencing for testing voltage, polarity, phase sync. angle etc., realizing fully automatic networks switching.
- Phase angle superposition for arbitrary lines.