Pulsed Sinusoidal Disturbances Immunity

Model:CST 10150DH

The pulsed sinusoidal disturbances immunity test system CST 10150DH is designed as per ISO 7637-4 and adopts all-in-one design, which integrate signal generator, RF power amplifier and RF power meter.

In Stock
Enquire Now

Description

The CST 10150DH is designed as per ISO 7637-4 and adopts all-in-one design, which integrate signal generator, RF power amplifier and RF power meter and each of them can be used independently. External power amplifier is optional as well as. Its frequency ranges from 100 kHz to 100 MHz. The CST 10150DH is controlled by PC software, so calibration and test can be conducted automatically, which greatly improves the test efficiency and system extendibility. The generated test result can be saved, printed or shared internally.

Features:

  • Integrate signal generator, RF power amplifier and RF power meter in one unit.
  • The creation of test templates makes software operation easy.
  • USB interface for PC remote control.

Standard

  • ISO 7637-4

Specifications

Technical Parameters
Model No. CST 10150DH
Standard ISO 7637-4 Pulse A
Frequency Range 1 μHz~100 MHz
Frequency Resolution 1 μHz
Frequency Stability over Temp. ±1 ppm+10 pHz

18℃~28℃

Harmonics DC~10MHz (including 10 MHz): <-55dBc 10MHz~20MHz (including 20 MHz): <-50dBc 20MHz~40MHz (including 40 MHz)::<-40dBc >40MHz:<-35dBc
Non-harmonics ≤10MHz:<-60dBc >10MHz:<-60dBc+6dB/Octave
Output Power ≤10MHz:1.0mVpp~10Vpp

≤30MHz:1.0mVpp~5.0Vpp

≤60MHz:1.0mVpp~2.5Vpp

>60MHz:1.0mVpp~1Vpp

Power Precision Typical(1kHz sinusoidal, 0V offset, >10mVpp,automatic)

± (1% of setting value) ±5mV

Power Meter Resolution 0.1 mVpp
Amplitude Modulation(AM) Modulation depth: 0%~120%;

Modulated rate: 2 mHz ~1 MHz

Frequency Modulation(FM) Modulated rate: 2 mHz ~1 MHz
Phase Modulation(ФM) Phase modulation :0°~360°;

Modulated rate: 2 mHz ~1 MHz

Pulse Repetition 1 μs ~ 500 s
Pulse Width 0 ns~100 s
Output Interface N (female)
VSWR <1.5:1
Technical Parameters (Power Meter)
Frequency Range 9 kHz ~ 6 GHz
Test Electrical Level -50 dBm ~ +20 dBm
Accuracy ±0.2 dB
Input Interface N (female)
VSWR <1.1:1
Technical Parameters (Power Amplifier)
Frequency Range 100 kHz ~ 230 MHz
Gain 51.7 dB±1 dB (150 W)
1dB Gain 51.7 dB±1 dB (150 W)
VSWR <1.5:1
Output Impedance 50 Ω
Output Interface N (female)
General parameters
Working Power AC 110 V/220 V ±10%,50 Hz / 60 Hz±5% (AC 220 V 50 Hz in mainland China)
Max. Power 500 W
Dimension 19″ / 4U
Weight About 15 Kg
Ambient Temperature 15 ℃ – 35 ℃
Relative Humidity 45%-75%
Atmospheric Pressure 86 kPa~106 kPa

Downloads