PFS single phase power fail simulator simulates voltage dip, interruption and variation which are caused by power grid and transformer devices due to malfunction or sudden large change of load. It is required to test this kind of phenomena to check whether electronic and electrical device can sustain safety operating condition. PFS 2216 SV is equipped with two semiconductor switch controlled independently. It can withstand impulse current and each switch has electronic protection function.

Features:

  • 5.7-inch color touch screen
  • Full compliant test as per IEC 61000-4-11, GB/T17626.11
  • Built-in multi functional test module
  • Data acquisition of voltage and current
  • Programmable test procedures
  • Ethernet RJ45, PC remote control, test report documentation and print

Standard

  • IEC 61000-4-11
  • IEC 61000-4-29
  • GB/T 17626.11
  • GB/T 17626.29
  • EN 61000-4-11
  • EN 61000-4-29

Specifications

General Parameters
Display 5.7 inch TFT touch screen
Power supply 110 V / 220 V, ±10%, 50/60 Hz
Fuse 6 A
Max. Power consumption 100 W
Memory space Infinite (PC)
Communication mode Ethernet LAN、RJ45
External control D-sub 25p
External trigger input BNC, 5 V TTL
CRO output BNC, 5 V TTL
Input BNC, 5 V TTL
Synchronization 45-65 Hz, 20-500 V between dotted terminal & undotted terminal
Warning LED 0-220 VAC 10 A/0-48 VDC 3 A
Depending on external signal lamp
Safety circuit Test only can be started when it is closed
Failure test Display on LCD and interrupt the work at failure case
EUT voltage monitoring output BNC,100:1 coaxial output
EUT current monitoring output BNC,10A:1 V coaxial output
Working indicator LED, LCD front panel display
Grounding connection Flat ground line
EUT power injection 4 mm banana line
Output mode Standard 1 m coaxial cable
Size 19 inch/6U/4U or 22U cabinet
Weight(different weight for different model) Eg. PFS 2210SVD / PFS 2210SD / PFS 2216SD  weight: 40 Kg;
PFS 1130D weight: 24 Kg or 100 kg (with the power supply)
Temperature 15 ℃ ~ 35 ℃
Humidity 45% ~ 75%
Air pressure 86 kPa ~106 kPa
Power fail test as per IEC6100-4-11&IEC61000-4-29,GB/T17626.29 for single phase AC and DC including voltage dips, short interruption and voltage variation
Power fail simulator
EUT max. Voltage PFS22xxSD, PFS22xxSVD series: 250 V AC,300 V DC
PFS05xxD series:55 V DC
PFS11xxD series:130 V DC
PFS12xxD series:140 V DC
PFS22xxD series:300 V DC
EUT max. current PFS2216SD、PFS2216SVD: 16 A  AC/DC continuous current;
                             20 A continuous 5 s; 40 Acontinuous 3 s;
PFS2210SVD、PFS2210SVD: 10 A  AC/DC continuous current;
                             12 A continuous 5 s; 25 Acontinuous 3 s;
PFSxx05D: 6 A
PFSxx010D:12 A
PFSxx20D: 22 A
PFSxx25D: 28 A
PFSxx30D: 33 A
PFSxx50D: 55 A
EUT power supply Single phase  no more than 230 V
50~60 Hz±5%
DC no more than 300 V DC
Offer DC control
EUT current and voltage measurement LCD display
BNC terminal:voltage 100:1, current 100 A : 1 V
Interrupt level 0%
Dips level 0%-100%(for accessories VVT/VMT series)
0%,40%,70%,80%(for accessories VVTxxxxSF series )
Repetition rate for dips and interruption 0.3-9999 cycle or 5 ms – 9999 ms
Duration for dips and interruption 50 ms – 50000 ms
Test time for dips and interruption 1 s – 9999 s
Rise and fall time for dips and interruption Generator rated current ≤ 75 A: 1-5 μs (standard resistance calibration)
Generator rated current >75 A: 1-50 μs (standard resistance calibration)
Voltage variation level 0-100%
Time for decreasing voltage 500 ms – 9999 ms(50%-100%)or abrupt(same with rise and fall time for dips and interruption)
1000 ms – 9999 ms(0%-100%)or abrupt(same with rise and fall time for dips and interruption)
Time for increasing voltage 500 ms – 60000 ms(50%-100%); 1000 ms – 60000 ms(0%-100%)
Time for reduced voltage 10 ms – 99999 ms
DC voltage level 0-120%
DC voltage change continuous 1 ms ~ 99999 ms
DC voltage change interval 50 ms ~ 50000 ms
Synchronization 0°~ 360°,1° step or random
Trigger mode Automatic, manual or external
Optional function Additional module for voltage variation test and two DC mains
Peak impulse capacity of simulator
Rated current Withstand current impulse capacity
PFS 2210SD 500 A
PFS 2210SVD 500 A
PFS 2216SD 500 A
PFS 2216SVD 500 A
PFS 2232SD 500 A
PFS 2232SVD 500 A
PFS 0505D 24 V/50 A, 48 V/100 A
PFS 0510D 24 V/50 A, 48 V/100 A
PFS 1110D 24 V/50 A, 48 V/100 A,110 V/220 A
PFS 1120D 24 V/50 A, 48 V/100 A,110 V/220 A
PFS 1125D 24 V/50 A, 48 V/100 A,110 V/220 A
PFS 1130D 24 V/50 A, 48 V/100 A,110 V/220 A
PFS 1150D 24 V/50 A, 48 V/100 A,110 V/220 A
PFS 2210D 24 V/50 A, 4 8V/100 A,110 V/220 A
PFS 2225D 24 V/50 A, 48V/100 A,110 V/220 A
PFS 2250D 24 V/50 A, 48 V/100 A,110 V/220 A
Simulator with rated current no more than 16 A meets the load capacity specified in IEC 61000-4-11
Rated current Load current capacity
PFS 2210SD
PFS 2210SVD
12 A  AC/DC continuous current; 15 A continuous 5 s; 25 A continuous 3 s;
PFS 2216SD
PFS 2216SVD
18 A  AC/DC continuous current; 20 A continuous 5 s; 40 Acontinuous 3 s;

Downloads