Direct-Current Power Failure Simulator PFS 0505D

Model:PFS 0505D

Direct-current power failure simulator PFS 0505D is specially designed generator for DC voltage dips immunity tests, capable of simulating conditions of voltage dips.

In Stock
Enquire Now

Description

Direct-current power failure simulator PFS 0505D is a specially designed generator for DC system immunity tests, capable of simulating conditions of voltage dips, short interruption and variation on the DC power input port. The equipment boasts intelligent control and automatic measuring with imbedded technologies, which simplify the system and stabilize the performance. The unique LCD operation and powerful human-machine interaction functions also bring more convenience.

Features:

  • 5.7” color touch screen front panel
  • Built-in multifunction modules
  • Test sequencing and scheduling
  • Ethernet RJ 45 interface for PC control, printing test reports

Standard

  • IEC 61000-4-29 2000
  • GB/T 17626.29-2009

Specifications

Technical Parameters
Rated Voltage 1 V-50 V, 0.1 V step
Voltage Dips / Surge Voltage 0-120%
Voltage Dips / Surge Duration 0.1 ms-59.999 s
Voltage Rise / Fall Time < 50 μs (generator loaded with 100 Ω resistive load)
Overshoot / Undershoot of the Output Voltage Less than 10% of the change in voltage (generator loaded with 100 Ω resistive load)
Time Intervals 0.1 s – 60 s (the min. time depends on the test voltage)
Measuring Accuracy Voltage: 1% (±0.1 V);
Current: 1% (±0.1 A);
Max. Output Current (Steady State) ≤ 5 A
Number of Tests 1 – 9,999
Ripple Content Less than 1% of the output voltage
Load Adjustment Rate Output voltage variation with the load (0 to rated current) < 5%
Output Impedance during a Short Interruption > 100 kΩ
General Parameters
Display Screen 5.7” TFT touch screen
Working Power Supply AC 110 V / 220 V (±10%), 50 Hz / 60 Hz (Default AC 220 V 50 Hz in mainland China)
Fuse 10 A
Max. Power Consumption 1,000 W
User’s Memory Space Infinite (PC)
Communication Mode Ethernet LAN, RJ45
Working Status Indication LED indication and LCD display on front panel
Dimension 19”, 4 U x 2 pcs
Weight Approx. 40 kg
Ambient Temperature 15 ℃ – 35 ℃
Relative Humidity 45%–75%
Atmospheric Pressure 86 kPa–106 kPa

Downloads

Adobe PDF

Reviews

There are no reviews yet.

Be the first to review “Direct-Current Power Failure Simulator PFS 0505D”

Your email address will not be published. Required fields are marked *