Common-Mode Conducted Disturbances Simulator CDS 300

Model:CDS 300

The CDS 300 conducted, common mode disturbances simulator can be controlled by CoreLab control software to conduct various functional tests in the frequency range from 0 Hz (DC) to 165 kHz.

In Stock
Enquire Now

Description

The CDS 300 conducted, common mode disturbances simulator can be controlled by CoreLab control software to conduct various functional tests in the frequency range from 0 Hz (DC) to 165 kHz, its voltage up to 300 V. It can perform tests under continuous mode and short-term mode at power frequency DC, 162/3, 50 Hz and 60 Hz as per IEC/EN 61000-4-16 and conduct step tests from 10 Hz to 165 Hz. Also, it satisfies test requirement specified in IEC 61000-4-19, IEC/EN 60255-22-7 and JJF 1245.4-2019. Together with different optional accessories, every test can be conducted as per different standard requirement.

Features:

  • All-in-one design
  • Frequency range DC~165 kHz
  • Test voltage up to 30 V in frequency range 10 Hz to 165 kHz
  • Test voltage up to 300 V at power frequency DC, 162/3 Hz, 50 Hz, 60 Hz
  • Frequency step: liner, logarithmic or fixed.
  • The efficient icon and standard library in CoreLab software make operation easy.

Standard

  • IEC 60255-22-7
  • GB/T 14598.19
  • IEC 61000 – 4 -19
  • IEC 61000- 4-16
  • EN 61000-4-16
  • EN 61000-4-19
  • EN 60255-22-7
  • JJF 1245.4-2019

Specifications

Technical Parameters in Continuous Mode
Power Frequency DC, 162/3 Hz, 50 Hz, 60 Hz
Open Circuit Voltage 1 V ~ 30 V
Signal Level (0.1 – 30) V (r.m.s.) or DC
Test Level 1 1 V, continuous
Test Level 2 3 V, continuous
Test Level 3 10 V, continuous
Test Level 4 30 V, continuous
Output Impedance 50 Ω ±10%
Total Harmonic Distortion <10% (sinusoidal)
DC Ripple <5%
Technical Parameters in Short-Term Mode
Power Frequency DC, 162/3 Hz, 50 Hz, 60 Hz
Open Circuit Voltage 10 V ~ 330 V
Signal Level (1 – 330) V (r.m.s.) or DC
Test Level 1 10 V, continuous for 1 s
Test Level 2 30 V, continuous for 1 s
Test Level 3 100 V, continuous for 1 s
Test Level 4 300 V, continuous for 1 s
Output Impedance 50 Ω ±10%
Total Harmonic Distortion <10% (sinusoidal)
Phase Sync 0° ±5%
DC Ripple <5%
Fall/Rise Time 1 μs – 5 μs
Technical Parameters in 15 kHz – 165 kHz
Power Frequency 10 Hz – 165 kHz
Signal Level (0.1 – 30) V (r.m.s.)
Test Level 1 1 V – 0.1 V – 1 V
Test Level 2 3 V – 0.3 V – 3 V
Test Level 3 10 V – 1 V – 10 V
Test Level 4 30 V – 3 V – 30 V
Output Impedance 50 Ω ±10%
Total Harmonic Distortion <1% (sinusoidal)
Technical Parameters in Differential Mode Voltage Disturbances
Frequency Range 2 kHz ~ 150 kHz
Waveform Sinusoidal, Total Harmonic Distortion (THD) <5%
Open Circuit Voltage 0.1 V ~ 20 V
Load Impedance 10 Ω ±30%
Technical Parameters in Differential Mode Current Disturbances
Frequency Range 2 kHz ~ 150 kHz
Max. Current 5 A
Load Impedance 1 Ω ±0.3 Ω
BNC Output 10:1 (0.1 V/A)
General Parameters
Power Supply AC 110/220 V, ±10%, 45 Hz ~ 65 Hz
Ambient Temperature 15 ℃ ~ 35 ℃
Dimension 22U
Weight Approx. 100 kg

Downloads