Coupling Networks CN14598-19

Model:CN14598-19

Coupling networks CN14598-19 is designed to evaluate whether the EUTs under rated frequency can operate normally when they are excited and suffered.

In Stock
Enquire Now

Description

CN14598-19 is designed to evaluate whether the EUTs under rated frequency can operate normally when they are excited and suffered from the power frequency disturbances of short-term, conductive, common-mode and differential- mode in DC static. Powerful coupling capability guarantees that the EUTs are capable of meeting the requirements of immunity performance in the process of power frequency testing and the parameters’ specification after finishing testings to ensure the test’s repetition. The coupling performance and transmission rate is stable. Compact size makes it easy to carry and use.

Characteristics:

  • As per GB/T 14598.19& IEC 60255-22-7.
  • Common mode and differential mode can be realized.
  • No additional protection for AE is needed.
  • Different mode of test can be realized by means of replacing limiting resistors.

 

Standard Schematic Diagram
Figure 1: Example for A-Level differential mode test

As per GB/T 14598.19—2007/IEC 60255-22-7:2003  Figure 2

Standard Schematic Diagram
Figure 2: Example for B-Level differential mode test

As per GB/T 14598.19—2007/IEC 60255-22-7:2003 Figure 3

Standard Schematic Diagram
Figure 3: Example for common mode test

As per GB/T 14598.19—2007/IEC 60255-22-7:2003 Figure 4

Test Connection Schematic Drawing
Figure1: differential mode test

Test Connection Schematic Drawing
Figure 2: common mode test

Standard

  • IEC 60255-22-7
  • GB/T 14598.19

Specifications

Technical Parameters
Standard GB/T 14598.19:2007, IEC 60255-22-7:2003
Model No. CN14598-19
Coupling Waveform Power frequency voltage wave, duration time is at least 10 s
Coupling Mode RC coupling, common mode and differential mode
Coupling Component 100 Ω /0.047 μF with a tolerance of ±5%, RC module, External
100 Ω /0.1 μF with a tolerance of ±5%, RC module, External
220 Ω /0.47 μF with a tolerance of ±5%, RC module, External
Operating Voltage Max. 100 V DC (100 Ω /0.047 μF) RC module 1
Max. 150 V DC (100 Ω /0.1 μF) RC module 2
Max. 300 V DC (220 Ω /0.47 μF) RC module 3
Test Setup The connecting length between EUT and coupling network shall be less than 2 m.
General Parameters
Weight 2.8 kg
Dimension 250 mm (L) × 200 mm (W) × 133 mm (H)
Enclosure Material Aluminum
Ambient Temperature 15°C – 35°C
Relative Humidity 45% – 75%
Package Case Carton

Downloads

Adobe PDF

Reviews

There are no reviews yet.

Be the first to review “Coupling Networks CN14598-19”

Your email address will not be published. Required fields are marked *