CDN for Communication Cable in Transient Immunity Test
Showing 1–12 of 20 results
-
CDN for Communication Cable in Transient Immunity Test
Surge Coupling/decoupling Networks for Unshielded Unsymmetrical Interconnection Lines CDN 405AF8-C
Model:CDN 405AF8-C
The CDN 405AF8-C is designed to conduct surge test on unshielded unsymmetrical interconnection lines as per figure 9 specified in IEC/EN 61000-4-5:2017.
Model:CDN 405AF8-C
The CDN 405AF8-C is designed to conduct surge test on unshi
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Dedicated Decoupling Networks for Power Energy Meter EMS Test System SND-10NF Series
Model:SND-10NF Series
SND-10NF series dedicated decoupling networks for power energy meter EMS test systems are used in conducting immunity tests of EFT/Burst.
Model:SND-10NF Series
SND-10NF series dedicated decoupling networks for power
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling/Decoupling Networks for Surge Testing on Unshielded Unsymmetrical Communication Lines CDN 21AF8
Model:CDN 21AF8
The CDN 21AF8 is designed to couple surge pulses onto 8 lines (4 pairs) unshielded unsymmetrical communication lines for voltage.
Model:CDN 21AF8
The CDN 21AF8 is designed to couple surge pulses onto 8 lines
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling/Decoupling Networks for Surge Testing on Unshielded Symmetrical High-Speed Communication Lines CDN 405
Model:CDN 405T8-CThe CDN 405T8-C is designed to conduct surge test on unshielded symmetric high-speed communication lines for data transmission rate up to 1,000 MBit/s.
Model:CDN 405T8-C
...
The CDN 405T8-C is de(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling/Decoupling Networks for Damped Oscillatory Waves Testing on Unshielded Symmetrical High-Speed Communication Lines CDN 418TH8
Model:CDN 418TH8
CND 418TH8 is designed for coupling damped oscillatory waves onto high-speed unshielded symmetrical communication lines in accordance with Standard IEC/EN 61000-4-18 and can be applied to ISDN.
Model:CDN 418TH8
CND 418TH8 is designed for coupling damped oscillatory waves
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling and Decoupling Networks for Data Cables and Control Cables CDN 405M40
Model:CDN 405M40The CDN 405M40 is designed in accordance with IEC 61000-4-5 and GB/T17626.5 and used for coupling surge onto 2-line (1-pair) unshielded unsymmetrical data and control cables for voltage up to 6 kV.
Model:CDN 405M40
...
The CDN 405M40 is desi(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling/decoupling networks for shielded cables CDN 405S8
Model:CDN 405S8Coupling/decoupling networks for shielded cables CDN 405S8 is designed in accordance with Standard IEC610000-4-5 and is applicable to shielded cables of 8-core.
Model:CDN 405S8
...
Coupling/decoupling net(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling/decoupling networks for shielded cables CDN 405S1
Model:CDN 405S1
Coupling/decoupling networks for shielded cables CDN 405S1 is designed in accordance with Standard IEC610000-4-5 and is applicable to shielded cables of one-core, to which surge tests are applied.
Model:CDN 405S1
Coupling/decoupling networks for shielded cables CDN 405S1 is
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling/decoupling networks for shielded cables CDN 405S9
Model:CDN 405S9
Coupling/decoupling networks for shielded cables CDN 405S9 is designed in accordance with Standard IEC610000-4-5 and is applicable to shielded cables of 9-core.
Model:CDN 405S9
Coupling/decoupling networks for shielded cables CDN 405S9 is
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling Decoupling Network CDN Mx
Model:CDN Mx Series
CDN Mx coupling decoupling network is suitable for power line testing of single-phase 1-wire/2-wire/3-wire, three-phase 4-wire, and three-phase 5-wire.
Model:CDN Mx Series
CDN Mx coupling decoupling network is suitable for power l
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Unshielded Symmetric Line Coupling
Model:CDN 405T8(POE 10KV)
CDN 405T8 (POE 10KV) coupling/decoupling network is suitable for (surge test) 4 pairs of 8-wire unshielded symmetric high speed (POE).
Model:CDN 405T8(POE 10KV)
CDN 405T8 (POE 10KV) coupling/decoupling network is
...(0 reviews) -
CDN for Communication Cable in Transient Immunity Test
Coupling decoupling network CDNE M2M3
Model:CDNE M2M3
The CDNE M2M3 is designed in accordance with the requirements of GB/T 6113.102-2018 and CISPR 16-1-2:2014 standards for measuring conductive disturbance of electrically small EUTs.
Model:CDNE M2M3
The CDNE M2M3 is designed in accordance with the requirements
...(0 reviews)