Automatic impulse current test system LCG

Model:LCG 50A

LCG 50A series impulse current generator test system has the advantages of high system integration, intelligent control, easy operation and so on.

In Stock
Enquire Now

Description

LCG 50A series impulse current generator test system has the advantages of high system integration, intelligent control, easy operation and so on. Through the combination of different main loop units, the output of the device is divided into multiple levels to achieve the test ability to broaden the output range. This series of equipment adopts automatic control, only need to perform a simple test requirement setting on the parameter setting page, you can complete the switch of each range, one key automatic run test.

Features:

  • Full color touch screen man-machine interface operation, simple operation;
  • PLC control system has strong anti-interference ability, stable and reliable operation;
  • The control function has manual, automatic and program control functions to meet different test requirements;
  • Multi-range wide range output, can test the minimum current 1kA;
  • Using thyristor constant current charging mode, effectively save energy waste;
  • With a variety of abnormal protection functions, sound and light alarm;
  • Automatic measurement and analysis of waveform parameters;

Standard

  • IEC 61643-1
  • GB/T 16896.2
  • GB/T 11032
  • YD-T 5098
  • GB18802.1-2002

Specifications

General Parameters
Working Power Supply AC220V ± 10%,50/60Hz 60A
Ambient Temperature 10 ~ 40℃
Relative Humidity 35% ~ 85%RH(without condensation)
Atmospheric Pressure Not greater than 0.5Ω
Technical Parameters
Output Waveform 10/350μs±10% current wave
Output Peak Current 1kA ~ 50kA±10%
Voltage Direction Positive/negative, (automatic switching)
Charging Time Within 80% charging time can be guaranteed in the 60 s full of more than 80% of the charging time can ensure finish in the 120 s
Charging Voltage Instability less than 1 line
Trigger Mode Automatic or manual; Can be triggered single time
Trigger Error Rate less than 1 line
Triggered Range 100% rated charging voltage
Phase Shift Angle Setting 0 ~ 360°Step 1°
Phase Control Accuracy ±3°