LCG D series impulse current test system is a multi-pulse test generator self-development by 3ctest with high integration.

In Stock
Enquire Now

Description

LCG D series impulse current test system is a multi-pulse test generator self development by 3ctest with high integration, automation control system and easy operation. With different optional modules, it can simulate corresponding waveforms with an all-in-one high voltage test system. By setting parameters on setup page, LCG D series test system can switch all kinds of waveforms automatically only with one button.

  • Color touch screen, easy to operate
  • PLC control system, high interference immunity, stable, and reliable;
  • Two-path pulse output, delay time 0~99.9μs adjustable
  • Min. test current is about 1kA
  • Controlled silicon charging mode to save energy
  • Protection function with Audible and visual alarm
  • Measurement and analyze waveform parameters automatically
  • with MCS2000 automatic control system

Standard

  • TB/T 3074
  • IEC 61643-1
  • GB/T 11032
  • GB 18802.1
  • UL1449
  • YD-T 5098
  • YD/T 1235.2

Specifications

Technical Parameters
Item 8/20μS current wave, two-path output
Output peak 35kA×2, 65kA×2, 120kA×2, 150kA×2
T1 front time 8μS ±10%
T2 wave tail time 20μS ±10%
Reversed overshoot <20%
Wave-front oscillatory <5%
Voltage polarity +/-, (automatic switch)
Waveform switch Automatic switch
Charging time 10s~999s
Charging voltage
instability
Less than 1%
External sync input 50Hz
Trigger mode Automatic or manual, single trigger available
Trigger malfunction ratio Less than 1%
Trigger range 100% rated charging voltage
Phase test range 0~360°
Operating load test Internal, 0~500V, 5A continuous supply
Display screen 10 inch TFT color touch screen
Measurement display resolution Better than 3%
Type of DUT MOV, TVS, GDT, SPD, mains surge protection device
DUT residual voltage <5kV
Current measurement
(optional)
Internal test box, Rogowski coil measurement, panel BNC output
Voltage measurement
(optional)
Internal test box, pureresistance voltage divider, panel BNC output
Oscilloscope MDO3012, optional
Insulation strength ≤500V RMS(common port COMMON to ground reference PE)
General data
Power supply AC220V±10%,50/60Hz
Temperature -10-+40℃
Humidity 35%-85%RH(no condensation)
Ground resistance No more than 0.5Ω
Structure Open style, control system split base system
Test room size 5M*5M(base)+3M*5M(control)
Operation table 1.8M(width)*1.1M(height)*1M(depth)
No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Wave

form of mains voltage is sine wave. The THD is <5%.

Technical parameters of standard model
Model LCG30D LCG65D LCG120D LCG150D
Two-path Test peak 30kA 65kA 120kA 150kA
Parallel test peak 60kA 130kA 240kA 300kA
Stored energy 20kJ 62.5kJ 160kJ 250kJ
Charging voltage 30kV 40kV 60kV 80kV
Supply mains AC220V 32A AC220V 50A AC220V 50A AC220V 100A
Weight 1000kG 1500kG 2000kG 3000kG