Lightning surge coupling decoupling

Model:SPN 3832TM

SPN 3832TM can realize fully automatic three-phase coupling and decoupling function. Supply AC/DC power for EUT and can be used with CCS series and CWS series.

In Stock
Enquire Now

Description

SPN 3832TM can realize fully automatic three-phase coupling and decoupling function. Supply AC/DC power for EUT and can be used with CCS series and CWS series. Other EUT voltage and current level can be customized according to customers’ requirement. It is manually choosing coupling lines and voltage can reach 6.6 kV (1.2/50μs). EUT MAX load capacity for AC 450 V(Lx-Lx), AC 250 V(Lx-N/PE), 32 A and DC 220 V, 16 A.

Features:

  • EUT MAX load capacity: AC 450 V (Lx-Lx), AC 250 V (Lx-N/PE), 32 A and DC 220 V, 16 A
  • Maximum current can reach 32 A
  • Manually select the coupling decoupling path.
  • As per EN/IEC 61000-4-5
  • Compatible with other brands of surge generators.

Standard

  • IEC 61000-4-5 2005 3-Phase Power Lines,Lx-Lx
  • GB/T 17626.5
  • EN 61000-4-5

Specifications

Technical Parameters
Standard EN/IEC 61000-4-5
Test voltage MAX 6.6 kV(1.2/50μs)
Test current MAX 3.3 kA(8/20μs)
Coupling port L1(DC+), L2, L3, N(DC-), PE
Coupling path Lx – Lx/N line to line

Lx/N – PE line to PE

Coupling switching mode Manual
Coupling capacitance 9 μF, 18 μF
Coupling resistance 10 ohm, 0 ohm
EUT load capacity MAX AC 450 V (Lx-Lx) 32 AMAX AC 250 V (Lx-N/PE) 32 A

MAX DC 220 V 16 A

Residual pulse voltage at the injection of EUT Less than 15% of test pulse voltage or 2 times rated voltage of CDN
General parameters
Work Power Supply AC 110 V / 220 V±10%, 50 Hz / 60 Hz(Default in mainland China:220 V)
Fuse 6 A
Max. Power 100 W
Operating Temperature 15 ℃ – 35 ℃
Operating Humidity 45%-75%
Operating air Pressure 86 kPa-106 kPa
Dimension 6U
Weight About 38 Kg