Micsig Differential Probe MDP702

Code: MDP702
Active differential probe, switchable

Attenuation 20:1 / 200:1
Input Impedance 16 MΩ 1.5 pF (diff) / 8 MΩ 3 pF
Bandwidth 200 MHz
Rise Time ≤ 1.75 ns
Max. Test Input 70 V (20:1) / 700 V (200:1)
Max. Input (grounded) CAT II 600 V
Input Cable Length 8 cm
Output Cable Length 120 cm
  • Only connect to a grounded (earthed) oscilloscope!
  • Now includes NABL Calibration Certificate.

1 year warranty

45,990.00 35,990.00

In Stock 2-3 Weeks

In Stock 2-3 Weeks

Description

The high-voltage differential probes of the MDP series are based on Micsig’s innovative SigOFITTM technology. They are characterised by a very low noise floor, excellent amplitude-frequency characteristics and industry-leading common mode rejection, enabling users to test high frequency and high voltage signals with ease. Micsig MDP series probes can be used with oscilloscopes from all manufacturers.

Features

  • 5 MHz bandwidth limitation: When measuring the FET switching frequency in most switching power supplies, the MDP probe effectively eliminates high-frequency noise.
  • Quick Zero: Short-circuit the test leads, press the zero button, the probe can be zeroed very quickly.
  • Dual range selection: Improves the signal-to-noise ratio, meets more test requirements.
  • BNC interface: Standard BNC interface, works with any oscilloscope.
  • USB power supply: Powered directly from the oscilloscope’s USB port via a Type-C cable.
  • Overvoltage alarm: LED flashes, buzzer “beeps” quickly and indicates an over-range alert.
  • Exceptionally compact: Much smaller than conventional differential probes.
Model MDP700 MDP701 MDP702 MDP703 MDP704 MDP705
Bandwidth 100 MHz 150 MHz 200 MHz 300 MHz 400 MHz 500 MHz
Rise time ≤ 3.5 ns ≤ 2.33 ns ≤ 1.75 ns ≤ 1.2 ns ≤ 0.87 ns ≤ 0.7 ns
Attenuation 20 : 1
200 : 1
20 : 1
200 : 1
20 : 1
200 : 1
20 : 1
200 : 1
20 : 1
200 : 1
20 : 1
200 : 1
Accuracy ±2 % ±2 % ±2 % ±2 % ±2 % ±2 %
Max. Differential Voltage ( DC+AC PK) 70 V (20 : 1)
700 V (200 :1)
70 V (20 : 1)
700 V (200 :1)
70 V (20 : 1)
700 V (200 :1)
70 V (20 : 1)
700 V (200 :1)
70 V (20 : 1)
700 V (200 :1)
70 V (20 : 1)
700 V (200 :1)
Max. Common Mode Input Voltage CAT I 600 V
CAT II 450 V
CAT I 600 V
CAT II 450 V
CAT I 600 V
CAT II 450 V
CAT I 600 V
CAT II 450 V
CAT I 600 V
CAT II 450 V
CAT I 600 V
CAT II 450 V
CMRR DC: > 80 dB
100 kHz: > 60 dB
10 MHz: > 30 dB
100 MHz: > 26 dB
DC: > 80 dB
100 kHz: > 60 dB
10 MHz: > 30 dB
100 MHz: > 26 dB
DC: > 80 dB
100 kHz: > 60 dB
10 MHz: > 30 dB
100 MHz: > 26 dB
DC: > 80 dB
100 kHz: > 70 dB
10 MHz: > 40 dB
120 MHz: > 26 dB
DC: > 80 dB
100 kHz: > 70 dB
10 MHz: > 40 dB
120 MHz: > 26 dB
DC: > 80 dB
100 kHz: > 70 dB
10 MHz: > 40 dB
120 MHz: > 26 dB
Input impedance 16 MΩ 1.5 pF (differential)
8 MΩ 3 pF (pF(each input to ground))
16 MΩ 1.5 pF (differential)
8 MΩ 3 pF (pF(each input to ground))
16 MΩ 1.5 pF (differential)
8 MΩ 3 pF (pF(each input to ground))
16 MΩ 0.5 pF (differential)
8 MΩ 1 pF (pF(each input to ground))
16 MΩ 0.5 pF (differential)
8 MΩ 1 pF (pF(each input to ground))
16 MΩ 0.5 pF (differential)
8 MΩ 1 pF (pF(each input to ground))
Output voltage ≤ 3 V ≤ 3 V ≤ 3 V ≤ 3 V ≤ 3 V ≤ 3 V
Overrange LED/buzzer LED/buzzer LED/buzzer LED/buzzer LED/buzzer LED/buzzer
Power supply USB Type-C USB Type-C USB Type-C USB Type-C USB Type-C USB Type-C
Power 2 W 2 W 2 W 2 W 2 W 2 W
Cable length input approx. 8 cm approx. 8 cm approx. 8 cm approx. 8 cm approx. 8 cm approx. 8 cm
Cable length output approx. 120 cm approx. 120 cm approx. 120 cm approx. 120 cm approx. 120 cm approx. 120 cm

Download

Downloads

Manual


Adobe PDF

MDP700 Manual

Language: English

Reviews

There are no reviews yet.

Be the first to review “Micsig Differential Probe MDP702”